BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Institute of Corrosion - ECPv6.15.18//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://www.icorr.org
X-WR-CALDESC:Events for Institute of Corrosion
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:Europe/London
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20200329T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20201025T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20210328T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20211031T010000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:+0000
TZOFFSETTO:+0100
TZNAME:BST
DTSTART:20220327T010000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:+0100
TZOFFSETTO:+0000
TZNAME:GMT
DTSTART:20221030T010000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=Europe/London:20210330T180000
DTEND;TZID=Europe/London:20210330T193000
DTSTAMP:20260406T105514
CREATED:20201001T102853Z
LAST-MODIFIED:20210302T105632Z
UID:10111-1617127200-1617132600@www.icorr.org
SUMMARY:Aberdeen Branch Event - ICorr Technical Event
DESCRIPTION:Date: 30/03/2021 \nEvent Type: ICorr Technical Event \nSpeaker: Dr George Sergi – VECTOR. Galvanic Corrosion Control of Reinforced Concrete: \nTopic: Galvanic Corrosion / CP Control of Reinforced Concrete; Lessons learnt from 20 years of Site Trials. Sacrificial anodes have been used in reinforced concrete structures for up to 20 years. This presentation reviews the performance of the oldest set of anodes used in enhanced patch repairs where anodes were placed at the periphery of the patch at around 600 mm spacing on centre. It demonstrates\, from results of current output and steel de-polarisation levels that the repair system is still functioning adequately. These prototype anodes\, designed for a 10-year life\, have continued to deliver a reduced but significant current complying with currently accepted criteria. The overall reduction in current was found to be adequately described by an ‘anode aging’ model where the current delivered is halved over constant time intervals\, enabling determination of an ‘aging-factor’. \nTime: 18:00: Finish* at 19:30 \nLocation: Webinar: Login Details will be provided following Pre-registration (as attached Flyer). This Webinar Event is Free and Open to all ICorr Members / Non – Members. \nFor registration: Please contact amirattarchi@gmail.com\n – Giving your Full Name and Stating – ICorr Member or Non- Member
URL:https://www.icorr.org/event/aberdeen-branch-event-icorr-technical-event-2/
CATEGORIES:Aberdeen Branch
END:VEVENT
END:VCALENDAR