Ask the Expert

The questions in this issue relate to painting galvanized steel and predicting CO2 corrosion in oil & gas upsteam operations.

Question:
How do you prepare galvanized steel before it is painted with an epoxy? PS
Answer:
Painting galvanized steel is quite simple as long as the correct steps are used. There are basically four alternative methods to prepare this surface for painting, T-Wash, etch priming, sweep blasting, and weathering. Ideally the surface should be treated immediately after galvanising, but if this is not possible then it can still be carried out later, although the surface must be thoroughly cleaned to remove all contaminants.

T-Wash is a phosphoric acid solution with a small amount of copper carbonate which reacts with the zinc surface and turns it black. An even black colouration confirms that the whole surface is free from grease, and etched ready for painting. The solution must be allowed to dry fully and should be painted as soon as possible, and withing 4 weeks. It should not be used on galvanizing that has been allowed to weather however. There are also other equivalent proprietary products.

Etch primers are similar to T Wash, in that they etch the surface ready for painting, however they have a major disadvantage over T-Wash in that there is no colour change of the surface, and there is thus no indication that the whole surface has been treated. They are however suitable for use on weathered steel.

Sweep blasting at pressures up to 40 psi can roughen the galvanised surface sufficiently to provide a key for the subsequent paint system without removing too much of the zinc surface. Only a fine copper slag, and not the more common angular iron grit should be used, and care needs to be taken to determine the stand off distance and angle of blast to ensure the optimum surface is obtained. Sweep blasting is also often used in conjunction with a chemical pre-treatment.

Exposing a galvanized surface to the environment is another method for preparing it for painting. This should be for a minimum of 6 months, after which the surface is cleaned with a stiff brush to remove the loosely adhering material, leaving a bright zinc metal surface. The surface is then thoroughly washed and allowed to dry fully before being painted.
In all cases, the paint system should be applied according to manufacturers’ recommendations.

It should also be mentioned, that there are some paints which have been specifically formulated to be applied directly to the galvanised surface, and thus no pre-treatment stage is necessary. BG

Question:
How accurately can you predict CO2 corrosion in upstream operations? BK
Answer:
To do full justice to the question really requires writing a major article and even a book. The European Federation of Corrosion (EFC) publication #23, CO2 Corrosion in Oil and Gas Production Design Considerations is an excellent reference, if a little dated now having been published in 1997. Reading through more recent papers on the subject presented at the annual NACE International Corrosion Conferences can provide an excellent source of current thinking and practice.

Nevertheless, it is useful to address the question in two steps. For a given set of conditions, firstly what is the likelihood of CO2 corrosion occurring; and secondly, if likely, in what form and rate will it occur.
While predictive models have become the immediate go-to especially as the computing power and sophistication of laptops, tablets and increasingly smart phones continues to grow exponentially, together with ready access to the internet, it is useful to take a breath to reflect on what simple rules generally are worth having to hand. Concerning the likelihood of CO2 corrosion occurring, the following rule of thumb is worthy of note:

PCO2 < 7 psi (0.5 bar) Corrosion Unlikely
7 psi (0.5 bar) < PCO2 < 30 psi (2 bar) Corrosion Possible
PCO2 > 30 psi (2 bar) Corrosion

An important additional qualification to the above rule is how the following partial pressure ratios, to take account of the presence of H2S if also encountered, effects the resulting corrosion process:

CO2/H2S > 500 CO2 Dominates
500 > CO2/H2S > 20 Mixed CO2/H2S
0 > CO2/H2S > 0.05 H2S Dominates

From a detailed system design and operating standpoint, and for developing a fit-for-purpose corrosion / integrity management strategy, clearly the above rules provide limited hard engineering insight and basis to work from. However, they provide a quick and simple appreciation of the situation ahead of launching into modelling – the latter is a necessary requirement regardless, but not without its challenges and limitation.

There is no one industry recognised, or accepted standard CO2 corrosion model. Over the years there has been a steady growth in the number models in use, in part driven by several of the major oil & gas companies producing their own in-house developed models. All the models are principally directed at predicting CO2 corrosion of carbon and low alloy steels.

It is also worth recognising here the work over many years of de Waard et al (Shell) for their significant openly published contribution to the understanding and key requirements of building a robust CO2 corrosion model and its sound application. In fact, many of the at least 17 models readily found via an internet / published technical papers search owe much to the leading fundamental and practical insight resulting from the work of de Waard et al. It should be noted that most models are empirical in origin based on lab and/or field data. The most extensive and widely recognised theoretically based CO2 corrosion model, a product of a Joint Industry Project (JIP) funded programme at the Ohio University, forms an integral part of Ohio’s Multicorp corrosion prediction software covering almost all key aspects of internal corrosion of mild steel oil and gas pipelines. If not a member of the Ohio JIP, access to the Mulitcorp software is subject to a user charge.

Ready and free access to the models may be limited but a good starting point readily accessible on the internet is: CO2 Corrosion Rate Calculation Model, NORSOK Standard M-506 Rev 2, June 2005. There are commercial models available at a cost, such as the Wood Group’s Electronic Corrosion Engineer ECETM ® tool designed to assist corrosion engineers through the quantitative estimation of corrosion rates, including CO2 corrosion modelling and prediction, and selection of corrosion-resistant materials; and Broadsword Engineering’s proprietary web-based CO2 corrosion model enpICDATM as part of the technical service they offer.

A comparative review of many of the models was presented in Paper No. 10371, NACE Corrosion Conference 2010, San Antonio, CO2 Corrosion Models for Oil and Gas Production Systems. Whereas Paper No. 05552, NACE Corrosion Conference 2005, Houston, entitled A Prophetic CO2 Corrosion Tool – But when is it to be believed? provides additional related background reading resulting from BP’s development of their model Cassandra.

All the models have their strengths and weakness that will to varying degrees be dependent on the specific application. It would be inappropriate here to advocate use of any one model above the others.

  • Understanding the current condition and operating details of a system is equally a critically important step to making a sound choice and subsequent application of model. Some key points to consider are:
  • Understanding the origin of the model to be used, and how it addresses 
 the key factors that will determine the predicted corrosion rate
  • Range of CO2 partial pressure and temperature applicable
  • How it computes pH and range of applicability
  • Flow regime and liquid velocity noting that CO2 corrosion is a mass 
 transfer controlled reaction
  • Presence of potential corrosion hot spots – e.g. bends, dead-legs, and 
 surface flow disturbances such as pre-existing corrosion, weld beads – 
 can profoundly affect the form of attack (general versus localised 
 metal loss)
  • Surface fouling/shielding due wax, scale, solids drop-out – can 
 profoundly affect the form of attack (general versus localised metal loss)
  • Effect of liquid hydrocarbon phase wetting
  • FeCO3 protective scale formation, its nature and stability – will profoundly 
 affect the form of attack (general versus localised metal loss)

Additionally

  • Presence of H2S – often results in very low general corrosion rates but 
 increased risk of pitting and few models are strong at predicting the joint 
 corrosive action and rate in the presence of CO2 + H2S
  • Presence of dissolved volatile organic acids (e.g. acetic acid/acetate) – 
 can significantly increase the actual corrosion rate
  • Risk of top-of-line corrosion (usually wet gas systems but also may 
 effect multiphase lines under stratified flow with a gas space) where 
 water condensation rate is a key factor; also the risk is exacerbated by the 
 presence of volatile organic acids and H2S
  • Presence of solids leading to erosion-corrosion – usually results in a 
 synergistic effect on resulting metal loss rate for cabon/low alloy steels 
 that may result in localised attack

Having given due consideration and attention to the above in selecting a model, which can be further helped by looking for field analogues to draw comparisons with, the predicted rates will generally be acceptable for design purposes – e.g. if carbon steel can be used with or without use of a corrosion inhibitor supported by a specified corrosion allowance as part of the required nominal pipewall thickness. Also, predicted rates can be used in support of conducting corrosion risk-based assessments as part of developing a fit-for-purpose corrosion management strategy. If the form of attack is likely to be localised from, for example, consideration of the above points or from inspection data, it is common to apply an escalation factor – typically a 2 or 3 multiplier – to the predicted base corrosion rate. Operating company guidance documents and practices may detail specific requirements for applying escalation factors. It is also important to recognise that poor operation of corrosion control measures such inhibitor treatment and system cleanliness can adversely affect the underlying value of originally predicted corrosion rates.

Effectively managing corrosion solely based on predicted corrosion rates once a system comes into operation is not recommended no matter how good a model is hailed to be. Modelling should be treated as complementary to having in place a proactive and robust risk-based corrosion monitoring and inspection programme that also provides a feedback loop to enable further improvement of a model.
Finally, can any of the models truly predict mm/y corrosion rates to two or even one decimal place? They may display computed rates to such a level, but this could well be more a function of how the software is written than the actual inherent accuracy of the model. Caution should be exercise when using and quoting model-generated predicted corrosion rates to such decimal place accuracy!
Don Harrop FICorr(Hon) FEFC(Hon), CorroDon Consulting Ltd.

Readers are reminded to send any technical questions for possible inclusion in this column. These should be sent to the editor at, brianpce@aol.com

Follow us on social media

General Enquiries

Institute of Corrosion
Corrosion House
5 St Peters Gardens
Marefair
Northampton
NN1 1SX

tel: + 44 (0)1604 438222
e-mail: admin@icorr.org

Related News

The CEOCOR2024 Congress is coming closer and closer

The CEOCOR2024 Congress is coming closer and closer

The CEOCOR2024 Congress is coming closer and closer. It is an in person congress, without any possibility for remote or virtual access. All info on www.ceocor2024.com, abstracts on info@ceocor.lu. Do not forget to register and to book your hotel room as soon as...

Standards Up-date ISO

The following documents have obtained substantial support during the past two months, and have been submitted to the ISO member bodies for voting, or formal approval. ISO/FDIS 4624 Paints and varnishes — Pull-off test for adhesion (Revision of 2016 standard) ISO/DIS...