According to a press release, the new OmniScan™ X3 64 flaw detector from Olympus, delivers improved power and performance to their phased array ultrasonic testing (PAUT) product line. This 64-channel instrument has the pulser capacity to drive phased array (PA) probes with a larger number of elements, increasing the data acquisition speed for total focusing method (TFM) imaging. Users can exploit its increased capabilities to expand and diversify their application portfolio.
The high portability and enhanced performance of the OmniScan X3 64 flaw detector increase inspection productivity. It can process TFM images up to four times as fast as its predecessor, yet comes in the same rugged and easily transportable box. On job sites with limited or restricted space, users will appreciate that the unit is compact and less cumbersome than other 64-channel devices. Inspectors can also remain on site longer and perform bigger scanning jobs without transferring data, thanks to the large 1 TB onboard storage.
Smaller defects are easier to distinguish using the flaw detector’s high-resolution PA and TFM imaging. Accommodating lower frequency probes, the OmniScan X3 64 unit can increase penetration in attenuative materials while reducing signal saturation. These improved detection capabilities assist monitoring for early-stage flaws, such as high-temperature hydrogen attack (HTHA), concluded the company.
For more details visit www.Olympus-IMS.com/phasedarray/OmniScan-X3.
The Corrosion Engineering Division (CED) of the Institute of Corrosion is delighted to announce that Professor Damien Féron will receive the Paul McIntyre Award at the 2025 ICorr Annual General Meeting (AGM), to be held at the Henry Royce Institute in Manchester on...
The Institute is delighted to announce that Brian Wyatt will be presented with the H.G. Cole Award at the 2025 ICorr Annual General Meeting (AGM), which will be held at the Henry Royce Institute in Manchester on Tuesday 4th November. The H.G. Cole Award is the highest...
The very first UK-China Corrosion Summit, jointly organised by the Institute of Corrosion (ICorr) and the Chinese Society for Corrosion and Protection (CSCP), was held in Manchester on 3–4 September 2025. The meeting gathered leading academics, practitioners, and...
We use cookies to optimize our website and our service.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.